Configures the circuit ID sub-option that identifies the VLAN for an incoming DHCP request.
vlan_info | Specifies a text string that becomes the circuit ID sub-option for the specified VLAN. Specify a text string composed of 1 to 32 characters. |
vlan_name | Specifies the VLAN to which the circuit ID sub-option is assigned. |
all | Specifies that the vlan_info entered is to be used in the circuit ID sub-option for all VLANs. |
The default vlan_info for each VLAN is the VLAN ID or tag.
The full circuit ID string uses the format vlan_info-port_info . To configure the port_info portion of the circuit ID string, use the following command:
configure bootprelay dhcp-agent information circuit-id port-information port_info port portTo display the vlan_info information, use the following command:
show bootprelay dhcp-agent information circuit-id vlan-informationThe following command configures the circuit ID vlan_info value VLANblue for VLAN blue:
configure bootprelay dhcp-agent information circuit-id vlan-information VLANblue blue
This command was first available in ExtremeXOS 12.4.
This command is available on all Universal switches supported in this document.